Product Description:
For managing the life of the air filter.
Operating principle:
The pressure gauge uses the measurement principle of the pressure gauge measures the difference in the air pressure equipment installed on the air pressure circuit.
The difference is measured while pressure, so you can achieve accurate and accurate measurements.
It is easy to install by simply combining the bypass circuit, so it is easy to install.
Easy to maintain, just monitor the pressure gauge.
RoHS
As a standard accessory, the pressure difference meter (GA400-8-P02) is a nylon tube (outer diameter φ4 x inner diameter φ2.5) 0.2 yd (0.5 m)
One end straight half union (connecting aperture R1/4 type MJS4-8), and one elbow union (connection aperture R1/4 type MJL4-8).
Please note that if the nylon tube is long 4.9 ft (1.5 m), please specify GA400-8-P02-T1.5.
JIS standards
[Other Specifications]
Maximum operating pressure: 1.0 MPa; Guaranteed pressure: 1.5 MPa; Fluid temperature (ambient temperature): 5 - 65 degrees; Difference pressure measurement range: 0 - 0.2 MPa; Pressure gauge accuracy: full scale ± 2.5 %; Connection aperture (high pressure side): R1/4
[Caution and Conditions]
Care Instructions:
When inserting the stop valve into the bypass circuit, make sure the stop valve is open.
Precautions for Use:
Please keep away from direct sunlight.
When using the compressed air temperature higher than the ambient temperature, the pressure gauge body is cooled by the ambient temperature.
There may be water droplets on the inside.
Image Notes: